| Battery Type: | Front Terminal VRLA Battery | Nominal Voltage: | 12V |
| Capacity Range: | 55Ah-200Ah | Terminal Type: | Front Access Terminal |
| Self-Discharge: | ≤3% Per Month | Operating Temperature: | -20°C To 50°C |
Camel Energy FT12 Series Front Terminal VRLA Battery is specifically designed for telecommunications, data centers, UPS systems and other critical standby power applications requiring high reliability and easy maintenance.
The battery adopts front terminal design and optimized plate structure, allowing direct installation into 19-inch and 23-inch standard cabinets while significantly reducing maintenance time and improving space utilization.
With excellent float charging performance, low self-discharge rate and long design life, the FT12 series has become one of the preferred backup power solutions for telecom operators, data centers and network infrastructure projects worldwide.
- Telecom Base Stations
- Data Centers
- Central Offices
- Fiber Access Networks
- Edge Computing Facilities
- UPS Systems
- Emergency Power Systems
- Industrial Control Systems
A front terminal battery is a valve regulated lead-acid battery in which both positive and negative terminals are located on the front side of the battery rather than on the top cover.
- Easier maintenance access
- Faster battery replacement
- Higher rack density
- Reduced installation space
- Lower operation and maintenance costs
For telecom cabinets and data centers where equipment density is high, front terminal batteries are widely considered the industry standard.
Compared with conventional top terminal batteries, FT batteries offer significant operational advantages.
| Feature | Top Terminal Battery | Front Terminal Battery |
|---|---|---|
| Maintenance Access | Top Access | Front Access |
| Rack Compatibility | Limited | Excellent |
| Space Utilization | Standard | Higher |
| Replacement Efficiency | Lower | Higher |
| Telecom Cabinet Integration | Moderate | Excellent |
| Data Center Application | Suitable | Preferred |
This is why front terminal batteries are widely deployed in:
- Telecom operator networks
- Internet data centers
- Fiber communication systems
- Edge computing facilities
- Front Access Terminal Design - Front-facing terminals simplify inspection, maintenance and replacement without removing adjacent batteries
- Optimized for 19-Inch and 23-Inch Cabinets - Compatible with standard telecom racks and battery cabinets
- Long Float Service Life - Designed for continuous float charging applications with a service life of up to 12 years under standard operating conditions
- Maintenance-Free Operation - Sealed VRLA construction eliminates electrolyte replenishment and routine maintenance
- Excellent High Rate Discharge Performance - Provides stable output during emergency power outages and generator transfer periods
- Low Self-Discharge - Supports long-term standby applications and improves backup system reliability
- High Reliability Grid Alloy - Advanced lead alloy formulation improves corrosion resistance and extends service life
- Reduce Telecom Cabinet Footprint - Front terminal design enables higher battery density in limited cabinet space
- Improve Maintenance Efficiency - Technicians can access terminals directly from the front without removing batteries from racks
- Lower Total Cost of Ownership - Reduced labor costs and longer service life improve project economics
- Suitable for Remote Sites - Maintenance-free operation is ideal for unmanned telecom stations and remote installations
- Reliable Critical Power Protection - Ensures uninterrupted operation of communication networks and data infrastructure
| Parameter | Typical Value |
|---|---|
| Battery Type | Front Terminal VRLA Battery |
| Nominal Voltage | 12V |
| Capacity Range | 55Ah-200Ah |
| Design Life | Up to 12 Years |
| Terminal Type | Front Access Terminal |
| Installation | 19"/23" Rack |
| Maintenance | Maintenance-Free |
| Self-Discharge | ≤3% Per Month |
| Operating Temperature | -20°C to 50°C |
| Application | Telecom and UPS |
Front terminal batteries place the terminals on the front panel for easier access and maintenance, while top terminal batteries require access from above.
Telecom cabinets have limited installation space and require quick maintenance access. Front terminal batteries maximize cabinet utilization and reduce maintenance time.
Yes. FT12 series batteries are widely used in UPS systems for data centers, hospitals, financial institutions and industrial facilities.
Yes. The maintenance-free design and excellent temperature performance make them suitable for both indoor and outdoor telecom applications when installed in appropriate cabinets.
Under recommended float charging conditions at 25°C, the design life can reach up to 12 years.
Yes. Camel Energy provides OEM branding, customized labels, terminal customization, rack integration solutions, telecom project support, and global distributor cooperation.