12V High Rate VRLA Battery for UPS and Data Center Backup Power
| Type: | 12V High‑Rate VRLA Battery | Voltage: | 12V |
| Rate Power: | 320W–850W (15min Rate) | Capacity: | 80Ah–250Ah |
| Application: | Data Center, UPS, High‑Rate Backup | Certifications: | ISO9001, ISO14001, IATF16949, TLC, CCS, CE |
| High Light: | 12V Uninterruptible Power Supply,320WVRLA Battery,850W valve regulated lead acid battery |
||
- Brand: Camel
- Type: 12V High‑Rate VRLA Battery
- Voltage: 12V
- Rate Power: 320W–850W (15min rate)
- Capacity: 80Ah–250Ah
- Application: Data Center, UPS, High‑Rate Backup
- Certifications: ISO9001, ISO14001, IATF16169, TLC, CCS, CE
- High current discharge capability
Camel Energy 6GFMHR Series is a high-rate discharge valve-regulated lead-acid (VRLA) battery specifically designed for mission-critical backup power applications requiring high instantaneous power output and short-duration discharge capability.
Unlike standard standby batteries that are optimized for long discharge periods, the 6GFMHR series is engineered to deliver 320W to 850W per cell over a 15-minute discharge period, making it ideal for:
- Data Center UPS Systems
- Modular Data Centers
- Edge Computing Facilities
- Telecom Base Stations
- Emergency Power Supply (EPS)
- Industrial Control Systems
- Financial Data Centers
- Hospital Critical Power Systems
The battery adopts high-conductivity plate design, low internal resistance technology, and optimized active material formulation to ensure stable voltage output during high-current discharge conditions.
Designed for float charging applications, the battery provides long service life, high reliability, and maintenance-free operation in 24/7 standby environments.
| Model | Power | Capacity | Dimensions (L×W×H/TH, mm) | Weight (kg) | Terminal |
|---|---|---|---|---|---|
| 6‑GFMHR‑320W | 320W | 80Ah | 260×168×208/212 | 23 | M6 |
| 6‑GFMHR‑360W | 360W | 90Ah | 330×171×214/220 | 27 | M6 |
| 6‑GFMHR‑400W | 400W | 100Ah | 330×171×214/220 | 29 | M8 |
| 6‑GFMHR‑430W | 430W | 110Ah | 330×171×214/220 | 31 | M8 |
| 6‑GFMHR‑480W | 480W | 120Ah | 406×174×208/237 | 35 | M5 |
| 6‑GFMHR‑600W | 600W | 150Ah | 485×172×240/240 | 42 | M8 |
| 6‑GFMHR‑630W | 630W | 160Ah | 485×172×240/240 | 46 | M8 |
| 6‑GFMHR‑700W | 700W | 200Ah | 522×238×218/223 | 60 | M8 |
| 6‑GFMHR‑750W | 750W | 220Ah | 522×238×218/223 | 65 | M8 |
| 6‑GFMHR‑850W | 850W | 250Ah | 521×269×220/223 | 72 | M8 |
- Hyperscale Data Centers
- Edge Data Centers
- Colocation Facilities
- 5G Base Stations
- Core Network Facilities
- Telecom Switching Centers
- SCADA Systems
- Process Automation
- Industrial Control Rooms
- Hospital UPS Systems
- Operating Rooms
- Medical Imaging Equipment
- Banking Data Centers
- Trading Platforms
- Disaster Recovery Centers
- Delivers 320W to 850W per battery at 15-minute discharge rate.
- Supports high-current discharge during utility outages.
- Designed specifically for short-duration, high-power backup scenarios.
- Excellent compatibility with online UPS systems and modular UPS systems.
- High conductivity grid alloy reduces energy loss.
- Maintains stable voltage during heavy load conditions.
- Designed for continuous float charging operation.
- Expected design life up to 12 years under standard operating conditions.
- Sealed VRLA structure eliminates electrolyte maintenance.
- No water addition required during service life.
- Pressure relief valve design ensures safe operation.
- Excellent resistance to thermal runaway and overcharge conditions.
Long service life reduces replacement frequency and maintenance costs.
High power density allows fewer batteries to achieve required backup power targets.
Provides stable power during the critical transfer period between utility failure and generator startup.
AI computing clusters generate highly dynamic loads and require batteries capable of supporting rapid load fluctuations and high discharge rates. High-rate VRLA batteries are increasingly used in modern AI data center UPS architectures.
A high-rate VRLA battery is a sealed lead-acid battery specifically optimized for delivering large amounts of power within a short discharge period, typically between 5 and 30 minutes.
High-rate batteries prioritize power output, while standard VRLA batteries prioritize energy capacity and longer discharge duration.
Most data centers only require battery backup long enough for diesel generators to start. High-rate batteries provide higher power density and lower footprint compared with conventional standby batteries.
Backup time depends on UPS load, battery quantity, and system voltage. Typical runtime ranges from 5 to 30 minutes.
Yes. The 6GFMHR series is widely suitable for modular data centers, edge computing facilities, and containerized data center projects.
Yes. Camel Energy provides OEM and ODM services including:
- Customized branding
- Private label production
- Terminal customization
- Cabinet integration support
- Project-level battery configuration services